Sabtu, 18 Mei 2013

Terumo Terufusion Syringe Pump TE-331 Ease of use and high performance are not mutually exclusive. That is what we prove with the Terumo syringe pumps. In order to minimize the risk of ADES, the Terumo syringe pumps are equipped with several safety features. The risk of reading mistakes or misprogramming of the flow rate will be reduced thanks to the large, orange coloured decimal point and the difference in size between the digits and the decimal places. The pumps are also equipped with a unique user friendly and ergonomically designed dial to help eliminate mistakes whilst programming the settings. When the flow rate is set higher than 10 mL/h the pump will give a warning sound. The syringe can no longer be wrongly placed thanks to the barrel detection function and the larger plunger clamps. The pumps meet the safety requirements of EN 60601-1, EN 60601-2, EN 60601-1-4 and EN 60601-2-24. All the syringe pumps can be used with 10, 20, 30 and 50 ml syringes from Terumo and other specified brands. The correctness of the flow rate is within 1% for mechanical accuracy and within 3% for accuracy including the syringe. The durability or life span of the pumps are 6 years provided that the pumps are handled according to the conditions prescribed on the packaging and in the manual. The normal shelf life of the battery in the pump is 12 months. Alarms available on TE-331 and TE-332: Occlusion (3 levels), Nearly empty, Syringe dislocated, Low Battery, Plunger/clutch disengaged, Infusion completion, AC/DC cable disconnection. Specifications Product Name: TERUFUSION Syringe Pump TE-331 Compatible Syringes 10, 20, 30 and 50 mL (TERUMO and specified brands) Range of Flow Rate Setting: 0.1-300 mL/h (for 10, 20 and 30 mL syringes) 0.1-999 mL/h (for 50 mL syringes) 0.1-1200 mL/h (special function for 50 mL syringes) Flow Rate Display Change: 0.1 mL/h steps (for settings from 0.1 to 99.9 mL/h) 1 mL/h steps (for settings from 100 to 999 mL/h) Flow Rate Accuracy: Mechanical Accuracy: ±1% Accuracy including syringe: ± 3% Occlusion Detection Pressure: Selectable from three levels. (Values are with use of TERUMO syringe) [III]: 800 ± 200 mmHg max. (106.7 kPa ± 26.7 kPa) [II]: 500 ± 100 mmHg max. (66.7 kPa ± 13.3 kPa) [I]: 300 ± 100 mmHg max. (40 kPa ± 13.3 kPa) Optional: 5 occlusion levels (100, 200, 300, 500 and 800 mmHg) Priming (purge rate): 300 mL/h ~ 1200 mL/h (Depending on syringe size) Alarms: Occlusion, Nearly empty, Low Battery, Plunger/Clutch disengaged, Syringe disengaged, AC/DC Cable disconnected. High flow warning when turning the dial over 10 mL/h (optional) Special Functions: Functions are selectable via internal switches: Delivery Limit setting: 0.1 – 999.9 mL (in 0.1 mL steps) When the limit is reached, an alarm will occur and the infusion will continue at KVO rate of 0.1 mL/h. Nearly Empty alarm setting: The time until the syringe is empty can be programmed. (from 3 to 60 min.) Max. Flow Rate: 1 – 1200 mL/h (in 1 mL steps) Syringe Brand Confirmation Memory function (last settings) Changeable flow rate during infusion Power Supply: 100 to 240 VAC, 50/60 Hz 12 to 15 VDC Operable duration using internal battery NiMH: Approx. 5 hours (using a new battery at flow rate of 5 mL/h and ambient temperature of 25°C, after charging at least 15 hours with the power off) Classification (acc. to IEC 60601-1): Class I and internally powered equipment, Type CF, Continuous operation, IPX4 (splashproof) External Dimensions: 322 (W) x 114 (H) x 115 (D) mm Weight: TE-331 ± 1.8 kg External Communication and Nurse Call Connec
tor: RS-232 or RS-485, Nurse call : 12 VDC, 1 A max.

Tidak ada komentar:

Posting Komentar